MODEL
DTDM
2-way, manually-operated, directional poppet valve
SERIES 1 / CAPACITY: 40 L/min. / CAVITY: T-13A
L-Control, C-Poppet
L-Control, H-Poppet
D-Control, C-Poppet
D-Control, H-Poppet
T-Control, C-Poppet T-Control, H-Poppet
This manually operated, 2-position, 2-way directional cartridge is a direct-acting, poppet-style valve used to control
the direction of flow in a hydraulic circuit. The valve is available in either a normally open or normally closed
configuration. Manual operation is achieved via Sun's Twist/Lock manual override mechanism and is designed for
intermittent (infrequent) use only. Due to the poppet-style construction, this valve has extremely low leakage.
TECHNICAL DATA
Maximum Operating Pressure 350 bar
Maximum Valve Leakage at 110 SUS (24 cSt) 0,7 cc/min.@350 bar
Operating Torque 1,2 Nm
Seal kit - Cartridge Buna: 990-413-007
Seal kit - Cartridge Polyurethane: 990-413-002
Seal kit - Cartridge Viton: 990-413-006
(L)CONTROL
L Twist/Lock (Detent) Manual Override
D Twist/Lock (Dual) Manual Override
T Twist (Momentary) Manual Override
(C)POPPET CONFIGURATION
C Normally Closed
H Normally Open
(N)SEAL MATERIAL
N Buna-N
E EPDM
V Viton
snhy.com/
DTDM
TECHNICAL FEATURES
This valve is designed for intermittent use such as a manual override. The manual control assembly has a mechanical life expectancy of approximately 7,000
cycles.
The momentary/twist control option "T" allows the operator to momentarily shift the valve by twisting the knob clockwise and releasing. Once released, the valve
returns to its normal position.
The detent/lock control option "L" allows the operator to shift the valve into a mechanically detented position by twisting the knob counter-clockwise. This detented
position will be maintained until the operator twists the knob clockwise and allows the valve to return to its normal position. Please note that the detented position
is not intended for load holding applications but for temporary shifting only.
The dual-operation control option "D" allows the operator to either shift the valve momentarily by twisting the knob clockwise or shift it into a mechanically detented
postion by twisting counter-clockwise. Please note that the detented position is not intended for load holding applications but for temporary shifting only.
The control on this valve is meant to be operated by a person's hand. The control should not be modified, for instance fastening a lever to the knob. Under no
circumstances should the control be operated by other mechanical devices.
Valves exhibit extremely low leakage rates; less than 10 drops/min. @ 5000 psi (0,7 cc/min @350 bar).
This valve is suitable for load holding applications when using the Normally Closed option. The detent mechanism in the manual override is meant for temporary
actuation.
Cartridges configured with EPDM seals are for use in systems with phosphate ester fluids. Exposure to petroleum based fluids, greases and lubricants will damage
the seals.
Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge
machining variations.
PERFORMANCE CURVES
Model Code Example: DTDMLCNCONFIGURATION OPTIONS